Percutaneous Jaundice Meter:
DHD-C Percutaneous Jaundice Meter physical sample and advantages
Large LCD displayTwo units displayed at the same timeAverage value display, more storageLithium battery, long standby timeContinuous measurement, no need to reset
Main Technical Parameters:
Measurement meth: light reflective
Light source: LED
Display: LCD
Indication error: 0~25 mg/ dL ± 1.0 mg/ dL
Power supply: Lithium battery (DC3.6V, 1000mAh ± 20%);Tests can be done more than 800 times after a fully charge;
Calibration color screen: white end face is 0, yellow end face is 16.0±1.0
Main Function
Simultaneous display of measurement units: displaying mg / dL & µmol / L in the meantime. Data Storage: 200 groups of measurement data
Average Calculation: It can measure the average value of 2-5 times
Start-up preparation time: Ready to use at startup, no preparation required
Battery voltage detection function: When the battery voltage of the tester is too low, the screen displays “Low Battery”
Automatic shutdown: Automatic shutdown after 10 minutes of non-working state
Battery display: Real-time display of battery power 
Charging display: The viewing screen shows “Charging … ” during charging.
Automatic charging protection: It will stop charging automatically at the time battery voltage charging arrive 4.2V±0.05V.
Jaundice is one of the most common symptoms in the neonatal period. Clinical reports show that 20% to 30% of newborns may have visible jaundice. And early neonatal pathological jaundice is prone to bilirubin encephalopathy, so it is important to screen for early pathological jaundice.
The percutaneous jaundice tester produced by our company applies optical fibre technology, photoelectric technology, electronic technology and data processing to percutaneous bilirubin measurement. The test is painless and harmless, as long as the probe is lightly pressed on the skin of the forehead of newborns and infants, the serum bilirubin concentration value can be directly measured in an instant. The instrument is small in size, light in weight, easy to operate and carry, which can be widely used in neonatal departments and paediatrics departments of grade hospitals for early screening of neonatal jaundice, and has a broad market application prospect.
The percutaneous jaundice tester produced by our company applies optical fibre technology, photoelectric technology, electronic technology and data processing to percutaneous bilirubin measurement. The test is painless and harmless, as long as the probe is lightly pressed on the skin of the forehead of newborns and infants, the serum bilirubin concentration value can be directly measured in an instant. The instrument is small in size, light in weight, easy to operate and carry, which can be widely used in neonatal departments and paediatrics departments of grade hospitals for early screening of neonatal jaundice, and has a broad market application prospect.